Retrospective Evaluation (2022-2025)
Retrospective Evaluation (2022-2025) of the Impact of M11 Telemetry Implants on Clinical Pathology Parameters in Beagle Dogs in Toxicology Studies
Sophie Galy, Emilie Cornaire, Olivier Boucheix, Stéphane Baudet*
Safety Pharmacology Department, Charles River Laboratories - Safety Assessment, Lyon, France
The development of new therapeutic modalities and the increasing implementation of 3Rs in safety pharmacology (SP) have led to integrating SP endpoints in regulatory toxicology studies, in particular continuous cardiovascular recording using telemetry implants. Nevertheless, surgical stress and maintained presence of a foreign body raised concerns about impact of such devices on hematological, biochemical and coagulation (HBC) parameters. Although no such impact was shown for toxicology studies using NHPs, Beagle dogs data are scarce, despite their continued widespread use. We retrospectively analyzed the impact of D.S.I. M11 implants on HBC in Beagle dogs, from five 2-week to 4-week toxicology studies (75 males (M) and 70 females (F); 6-13 month-old on Day 1; administration routes: oral (4 studies) and intramuscular (1 study); control animals received standard vehicles). M11 body was placed between abdominal muscles, the pressure catheter was inserted in the aorta and ECG electrodes were placed subcutaneously in Lead II, with 3 weeks elapsing between surgery and the first pretreatment HBC determination. Individual HBC values were averaged per parameter and per sex (n=34 to 75), using pretreatment and dosing period data for controls and pretreatment data for treated groups. Those mean values were compared with contemporary historical control values (data from up to 548 M and 507 F), using Welch's t-test and 95% confidence intervals. No notable effects of M11 implants were noted on HBC, especially for markers of acute inflammation and presence of a foreign body. Minor increases were noted for creatine kinase (x1.3), likely reflecting surgically-induced muscular damage, and for reticulocytes (x1.2), likely reflecting reactive erythropoiesis and tissue repair. Therefore, the maintained presence of M11 implants in toxicology studies conducted in Beagle dogs was devoid of effects on standard clinical pathology parameters, strengthening confidence in using such implants for a refined assessment of drug safety on cardiovascular function.
Mots Clés : toxicologie, chien, télémétrie, cardiovasculaire, biologie clinique.
Évaluation préclinique de SENS-601
Évaluation préclinique de SENS-601, une thérapie génique pour le traitement de la surdité liée à...
Toxicological risk assessment of essential oil diffusers
Toxicological risk assessment of essential oil diffusers: addressing uncertainties in hazard...
Anticipation non clinique du risque de toxicité
Anticipation non clinique du risque de toxicité des inhibiteurs de points de contrôle...
Chronic heated tobacco aerosol exposure
Chronic heated tobacco aerosol exposure elicits divergent pulmonary molecular and functional...
Multi-Source Transcriptomic Comparison
Multi-Source Transcriptomic Comparison Identifies Shared Toxicological Mechanisms and a Core...
Systemic Toxicity Assessment for cosmetics
Systemic Toxicity Assessment for cosmetics: Status 13 Years After Animal Testing BanMarlène...